The software has been updated with several important changes. The ability to specify search location coordinates via the log file has been added. The signal table has been improved: signals can now be stored separately for each date, new fields have been added (RSSI, accumulated maximum, time of first and last detection, operator notes), as well as the ability to select the signal display mode. The signal recognition algorithm has also been significantly improved.
New capabilities have appeared in the signal analysis mode: the “History” function has been added, which allows finding signals from previous search sessions, display on the scales has been improved, and integration of peak values has been added. In addition, work with large logs and automatic log recording upon activation of the search mode have been improved. A report creation function has also appeared, which allows generating reports in HTML or PDF formats.
New features and changes
- Specifying search location coordinates (Log file – GNSS coordinates)
- New signal table capabilities:
- Storing signals separately for each date
- New fields added:
- RSSI Level (absolute signal level that does not account for masking)
- Accumulated maximum RSSI
- Time of first detection
- Time of last detection
- Text note (operator comment)
- Added recognition of all signals, not just dangerous ones
- Option to select signal display mode: “dangerous only” or “all”
- Improved signal recognition algorithm
- New functionality in signal analysis mode:
- RSSI Level
- Time of first and last detection
- Editing note
- “History” function
- “History” function. Allows finding a signal in previous search sessions to assess its level of danger:
- Scans the data folder and displays the logs and dates where a similar signal is encountered, as well as the coordinates of these logs and the registered signal parameters – bandwidth and RSSI level.
- The list can be exported for display on a map
- Improved display on scales:
- Added slight integration of peak values, which facilitates the localization of short-term pulse signals
- Increased brightness of the accumulated maximum level display
- Improved application performance with large logs that are created after searching in 24 hours a day mode
- “Automatic Log Recording” function ensures automatic turning on of log recording upon activation of the search mode
- “Report” function allows the operator to generate a report to an html/pdf file and report to the customer (management) after the search is complete